Working with groupings

Groupings are generally used to apply FMD operations to existing business processes. Either business processes such as deliveries are processed together, or packages are grouped into sales units such as cartons or pallets.

The groupings therefore reflect the respective structures of the customers’ operational processes and are used to make work easier. However, they can also be used to communicate with the outside world: external packaging data can be imported via groupings, reports can be generated for groupings, and aggregation functions can be used to transfer groupings in bulk to other users.

Here is an outline of a typical workflow for a pharmaceutical logistics provider:
An order for 2,000 packs is to be cancelled. The order must be documented.

Order acceptance, start of process

The order is displayed on a screen in the company-wide WMS. A barcode appears alongside the order, showing the order number po7931465, and the number of products to be scanned is displayed.

As a first step, this barcode is scanned from the WMS screen using the medAspis Speed Scanner. The PO number now provides the grouping name for the grouping to be processed. As the order is large and needs to be completed quickly, two operators work on it at the same time. The second operator also scans the same code from the WMS screen.

Both operators scan the packs for the order in the FMD operation VERIFY. The pack data from both medAspis Speed Scanners is stored in group po7931465. The current count is synchronised with both medAspis Speed Scanners. Both operators are therefore aware of the current shared scan progress.

As soon as the batch reaches the target of 2,000 packs, the two medAspis Speed Scanners stop. The laser scanners switch off automatically, and no further packs can be added to the batch.

Both operators close the grouping po7931465 by clicking the ‘Complete’ and ‘Confirm’ buttons.

Although the packs are to be deactivated according to the task description, in this first step they are initially only verified and are not deactivated until later. This step-by-step approach has operational advantages:

  • It can never be ruled out that a scanner might accidentally detect 2D matrix codes on packs that are not actually intended for processing. If these packs are then accidentally deactivated and nobody notices the error, they may no longer be fit for sale and will be excluded from further processing.
  • The medAspis Speed Scanners can be configured so that only the ‘Verification’ option is available in the FMD menu.
  • Verifikationen erfassen den 2D Matrixcode und speichern ihn für spätere Operationen im Lean FMD System.
  • Subsequent FMD operations can be carried out at any time and may fit in better with the operational workflow. The later the deactivation takes place, the better one can respond to any changes in orders.

Further processing in the Control Panel

The group can now be found under this name in the Control Panel. The ‘Groups’ menu item lists all the groups that have ever been created. The most recent group is usually at the top of the list.

Once the final packs have been entered and the process has been finalised by selecting ‘COMPLETE’ on the medAspis Speed Scanner, the batch is assigned the status ‘COMPLETED’. This status can be retrieved from the WMS via the medAspis API. The progress of the process can be automatically recorded in the WMS.

The grouping is checked (number of packs, product purity, batch number if applicable) and can be deactivated with a single click (including via the WMS). A report can be generated immediately from the grouping view to send the order, including all serial numbers and FMD statuses, to the customer and the client. Reports are generally generated in accordance with our customers’ individual specifications.

Ordering new Aggregation Codes

Please allow up to 24 hours for your order to be processed. We will then send the newly generated Aggregation Codes as a PDF to the email address provided here.

Please enter the number of Aggregation Codes you required:

Request a Replacement Device

Is your FMD Speed Scanner no longer working? To ensure you can continue working without interruption, we will send you a replacement device as quickly as possible. At the same time, you will receive a return label for sending back your defective device.

You will receive the replacement unit regardless of whether your warranty is still valid.

Terms of service

Support for counterfeit alerts

Do you suspect counterfeiting? Our medAspis Alert Team will assist you with the process. We are also happy to assist you with unclear error messages or unfamiliar situations.

Describe the incident using the report form. If needed, you can upload up to three photos. We will contact you as soon as possible and support you with the next steps.

Please enter an alert category:
Photos of packs, the Control Panel or the display of the FMD Speed Scanner
(max. 3 photos)

Compliance Check-up: FMD under review

Companies in the pharmaceutical industry are validated and meet strict quality requirements. Nevertheless, there is still a significant compliance risk with FMD.

Suspected falsification cases may not be handled and documented in a GxP-compliant manner.

With our free, anonymous and non-binding Compliance Check-up, we analyse and assess your company’s critical FMD error messages.

Review compliance

Based on your existing FMD audit trails, we analyse among other things:

The analysis is performed entirely within your data system. No data is transmitted to medAspis. All evaluations remain anonymous.

Request Compliance Check-up

Is there a specific reason for the Compliance Check-up?

Error messages

Download the error messages directly to your computer in your local language.

Error messages

Can’t find your language? As soon as you become a customer, we’ll of course provide the error messages in your local language. Promise.

Systematic Validation

medAspis stands for proven quality and traceable processes. Lean FMD provides the necessary framework for this.

Validated and Documented

Lean FMD is validated in accordance with EU-GMP Annex 15. medAspis operates a Quality Management System in accordance with ISO 9001 and supports you with validation and the required documentation.

Validation toolkit

With the Validation Toolkit, you receive the documentation for the validation of Lean FMD. This enables you to carry out the necessary validation steps in a structured and traceable manner.

Download an excerpt from the Validation Toolkit to get a first impression of the structure and process of validation.

The complete toolkit contains all the necessary documents for validating Lean FMD.